Reference Table For Setting Dispensing Time
& Dispensing Volume

Dispensing
Switchs
Dispensing Grease Volume
Time Setting
(ON)
Daily (24hrs)
Weekly (7 days)
Monthly (30 days)
1 Month
1
5.00 ml
35.00 ml
150.00 ml
2 Months
2
2.50 ml
17.50 ml
75.00 ml
3 Months
1 + 2
1.67 ml
11.67 ml
50.00 ml
4 Months
4
1.26 ml
8.75 ml
37.50 ml
5 Months
1 + 4
1.00 ml
7.00 ml
30.00 ml
6 Months
2 + 4
0.83 ml
5.83 ml
26.00 ml
7 Months
1 + 2 + 4
0.71 ml
5.00 ml
21.43 ml
8 Months
8
0.63 ml
4.38 ml
18.75 ml
9 Months
1 + 8
0.56 ml
3.89 ml
16.67 ml
10 Months
2 + 8
0.50 ml
3.50 ml
15.00 ml
11 Months
1 + 2 + 8
0.45 ml
3.18 ml
13.64 ml
12 Months
4 + 8
0.42 ml
2.92 ml
12.50 ml

Reference Table For Lubrication Period For Time Settings

Interval of days
Time setting
Inner diameter of bearing
Grease gun cycle
strokes
300 - 360 days
10 ~ 12 M
Under 38 mm
Monthly 5 ~ 8
240 days
8 M
38 mm ~ 50 mm
Monthly 8 ~ 12
180 days
6 M
51 mm ~ 62 mm
Bi-monthly 8 ~ 12
120 days
4 M
63mm ~ 72 mm
Weekly 5 ~ 8
90 days
3 M
73 mm ~ 85 mm
Weekly 8 ~ 12
60 days
2 M
86 mm ~ 100 mm
Every 3~4days 5 ~ 8
30 days
1 M
Over 100 mm
Every 1~2days 5 ~ 8
¡@
Notice : These tables are for references only. The final settings should be determined by the RUNNING HOURS, LOAD, TEMPERATURE, DUST...etc, especially the type of  grease used.
/ How it works /
¡@